Ideal for applications where water is prone to freeze in and around the seal support system.
ICEGUARD continually senses the temperature of the water inside the seal support system. The flow generated prevents the liquid inside the system from freezing.
The vessel can have a level switch installed so that an alarm can be sounded when the vessel is almost full & a flanged bottom so that internal cleaning can be administered
In API Plan 65 arrangements, leakage from the seal faces is collected via a drain port and directed to a liquid-collections system via a vessel equipped with a high-level alarm.
The 'Special Oil Unit' is suitable for many industries and is designed in accordance with the specifications set by the API Plan 54 forced circulation piping plan.